Products Products Center

YB-LdB-1 A-0 Deck

产品介绍: 1、Type of construction2、Technical Index   ClassificationProject NameTechnical IndexDamping   coatingThe flammability test of the surfaceComply with IMO 2010 FTP Code Part 5The flue gas and toxicity testComply with IMO 2010 FTP Code Part 2Deck   CoveringDensity≤1900kg/m3FluidityΦ≥130mmBreaking   Strength≥3.5MPaCompressive   Strength≥10MPaNoninflammabilityComply with IMO 2010 FTP Code Part 5Integral   StructureFire   ResistanceComply with IMO 2010 FTP Code Part 5Sound   Insulation Index≥35dBWeight   per unit area≤30.5kg/m2 3、The performance characteristics   The refractory deck has good floating performance, and can effectively reduce the noise and vibration noise.This deck is applicable to sound insulation,high-demanding shipping space. 4、 Fire resistance rating The flammability of the surface:Comply with the 1974 SOLAS IMO 2010 FTP Code Part 5. 5、Recognised classification society DNV.GL 、CCS 、EC     6、Packaging and dosage (per square metre to calculate)Serial No.Mterial NamePacking SpecificationDosage1AC-JIII Refractory Deck Covering25kg/bag1.02bag2DP-SDI Damping coating20kg/barrel0.01barrel 7、Construction technology   7.1 The steel deck need be rust-protect treatment,it is no oil pollution,dust and other contaminants on the surface;   7.2 Brush the DP-SDI Damping coating on the steel deck;   7.3 After the DP-SDI Damping coating curing,Paste a circle of surrounding edge blue bar on the steel casing ;   7.4 Using pumping machine to pump or dump the deck covering which mixed on the damping,use a foam roller to remove the air bubbles in the deck covering, and promote the flow of the deck covering ;   7.5 After the deck covering curing,hook out of the surrounding edge article blue and filled with rock wool;   7.6 After construction of deck covering must be curing 12 hours,after basic dry can walk on it; 8、Note   8.1 After mixing,the deck covering must be finished laying within one hour, if manually stirring must be stirring evenly;   8.2 During the deck covering construction and curing, the environmental temperature should be in 10 ~ 35 ° C.When the temperature above 35 ℃ cooling measures should be taken;When the temperature lower 0 ℃  heat preservation measures should be taken;   8.3 The deck covering should be moistureproof, prevent bask in, and stored in a ventilation environment.Material shelf life is 6 months;
Features: The refractory deck has good floating performance, and can effectively reduce the noise and vibration noise.This deck is applicable to sound insulation,high-demanding shipping space.
Fire rating: The flammability of the surface:Comply with the 1974 SOLAS IMO 2010 FTP Code Part 5.
Parameter DNV.GL 、CCS 、EC
颜色:
注意事项:

1 After mixing,the deck covering must be finished laying within one hour, if manually stirring must be stirring evenly;

2 During the deck covering construction and curing, the environmental temperature should be in 10 ~ 35 ° C.When the temperature above 35 ℃ cooling measures should be taken;When the temperature lower 0 ℃  heat preservation measures should be taken;

3 The deck covering should be moistureproof, prevent bask in, and stored in a ventilation environment.Material shelf life is 6 months;

 

  • Details
  • Precautions
  • Features

 

1、Type of construction

QQ截图20151208002135.png

2、Technical Index

  

Classification

Project Name

Technical Index

Damping   coating

The flammability test of the surface

Comply with IMO 2010 FTP Code Part 5

The flue gas and toxicity test

Comply with IMO 2010 FTP Code Part 2

Deck   Covering

Density

≤1900kg/m3

Fluidity

Φ≥130mm

Breaking   Strength

≥3.5MPa

Compressive   Strength

≥10MPa

Noninflammability

Comply with IMO 2010 FTP Code Part 5

Integral   Structure

Fire   Resistance

Comply with IMO 2010 FTP Code Part 5

Sound   Insulation Index

≥35dB

Weight   per unit area

≤30.5kg/m2

 

3、The performance characteristics

   The refractory deck has good floating performance, and can effectively reduce the noise and vibration noise.This deck is applicable to sound insulation,high-demanding shipping space.

 

4、 Fire resistance rating

 

The flammability of the surface:Comply with the 1974 SOLAS IMO 2010 FTP Code Part 5.

 

5、Recognised classification society

 

DNV.GL 、CCS 、EC

 

 

 

 

 6、Packaging and dosage (per square metre to calculate)

Serial No.

Mterial Name

Packing Specification

Dosage

1

AC-JIII Refractory Deck Covering

25kg/bag

1.02bag

2

DP-SDI Damping coating

20kg/barrel

0.01barrel

 

7、Construction technology

   7.1 The steel deck need be rust-protect treatment,it is no oil pollution,dust and other contaminants on the surface;

   7.2 Brush the DP-SDI Damping coating on the steel deck;

   7.3 After the DP-SDI Damping coating curing,Paste a circle of surrounding edge blue bar on the steel casing ;

   7.4 Using pumping machine to pump or dump the deck covering which mixed on the damping,use a foam roller to remove the air bubbles in the deck covering, and promote the flow of the deck covering ;

   7.5 After the deck covering curing,hook out of the surrounding edge article blue and filled with rock wool;

   7.6 After construction of deck covering must be curing 12 hours,after basic dry can walk on it;

 

8、Note

   8.1 After mixing,the deck covering must be finished laying within one hour, if manually stirring must be stirring evenly;

   8.2 During the deck covering construction and curing, the environmental temperature should be in 10 ~ 35 ° C.When the temperature above 35 ℃ cooling measures should be taken;When the temperature lower 0 ℃  heat preservation measures should be taken;

   8.3 The deck covering should be moistureproof, prevent bask in, and stored in a ventilation environment.Material shelf life is 6 months;

 


1 After mixing,the deck covering must be finished laying within one hour, if manually stirring must be stirring evenly;

2 During the deck covering construction and curing, the environmental temperature should be in 10 ~ 35 ° C.When the temperature above 35 ℃ cooling measures should be taken;When the temperature lower 0 ℃  heat preservation measures should be taken;

3 The deck covering should be moistureproof, prevent bask in, and stored in a ventilation environment.Material shelf life is 6 months;

 

   The refractory deck has good floating performance, and can effectively reduce the noise and vibration noise.This deck is applicable to sound insulation,high-demanding shipping space.

Copyright ©2005 - 2015 Bo Ltd. Suzhou billion