1、Type of construction
1)The construction of the damping coating and deck covering

2)The PDP system (galvanized steel +damping coating + galvanized steel)

2、Technical index
Serial Number | Project Name | Technical Index |
1 | Viscosity | Part A≥90mPa.s,Part B 10000-14000mPa.s |
2 | Density | ≤1300 kg/m3 |
3 | Organic Content | ≤55% |
4 | Surface Drying Time | ≤5 h |
5 | Tensile Strength | ≥2.0 MPa |
6 | Elongation at Rupture | ≥70% |
7 | Adhesive Force | ≥1.8 MPa |
8 | (邵A)Hardness | 60±5 |
9 | Loss Factor | ≥0.5 Under the normal temperature 20℃ |
10 | Low Flame-Spread | Accord with IMO 2010 FTP Code Part 5 |
11 | Smoke and Toxicity | Accord with IMO 2010 FTP Code Part 2 |
3、The performance characteristics
This product has excellent damping noise reduction features;Easy to construction;After curing non-shrinkage;Products without solvent, green environmental protection;Coating with no seams, smooth appearance.
4、Fire resistance rating
Surface flammability: comply with 1974 SOLAS IMO 2010 FTP Code Part 5.
Flue gas and toxicity: comply with 1974 SOLAS IMO 2010 FTP Code Part 2.
5、Recognised classification society
GL 、CCS 、EC
6、Packaging and dosage (per square metre to calculate)
Serial Number | Material Name | Packing Specification | Dosage |
1 | DP-SDI Damping Coating | 20KG/Bucket | 0.01Bucket |
7、Construction technology
7.1 The steel deck need remove rust, oil, dust and other sundry, and brush anti-rust primer;
7.2 Mix stir well the part A and B of the damping coatings.
7.3 Brush the damping coating DP - SDI evenly on the steel deck .
8、Note
8.1 After mixing,the damping coating must complete to lay within 30 minutes.
8.2 This product should be stored in a cool, ventilated, dry, it is strictly prohibited to the rain, the sun,fire, away from heat source, storage temperature should be 15 ~ 40 ℃.